Reliability Increaseof BaseHeating Prediction and Thermal Protection Methodology for Launch Vehicle Upper-Stage
Bao Yiying,Ding Yifu,Wang Pingyang,Liu Zhenhua
Table 2
The computed total heat flux and the measured total heat flux
Serial number of the heat flux sensor
the computed total heat flux
(kW/m
2
)
the measured total heat flux
(kW/m
2
)
Percentage error
1
11.6
5.6~10.1
14.9%
2
22.6
16.7~22.3
1.3%