Reliability Increaseof BaseHeating Prediction and Thermal Protection Methodology for Launch Vehicle Upper-Stage
Bao Yiying,Ding Yifu,Wang Pingyang,Liu Zhenhua
Table 2 The computed total heat flux and the measured total heat flux
Serial number of the heat flux sensor the computed total heat flux
(kW/m2)
the measured total heat flux
(kW/m2)
Percentage error
1 11.6 5.6~10.1 14.9%
2 22.6 16.7~22.3 1.3%